Mfg Part Number: 136CM4-12 | Alternate P/N: 136CM412 |
NSN : 5945-01-229-0743 | NIIN : 012290743 |
CAGE Code : 11532 | Manufacturer: Teledyne Reynolds Inc |
Item Name : Relay Electromagnetic | FSC : 5945 Relays and Solenoids |
Alongside NSN 5945-01-229-0743 we have countless other items from Teledyne Reynolds Inc and other leading manufacturers that are readily available for purchase. Nascent Aero lists parts alongside applicable CAGE Codes for the benefit of your search process, such as this particular NSN part 136CM4-12 being produced under the CAGE Code 11532. As our team members are always available for customers at all times, we guarantee responses to completed quote requests within 15 minutes of submission. Additionally, our team members can walk you through the purchasing process with person-to-person communication every step of the way, ensuring that all your needs are thoroughly and efficiently met. If you have any questions or concerns regarding our offerings and wish to speak with a representative, give us a call or email at any time; we are available 24/7x365.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-229-0743 Item Description: RELAY,ELECTROMAGNETIC | 5945 | 012290743 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
136CM9-12 | 5 | 8 | E |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 0.435 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.375 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.335 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AGAV | END ITEM IDENTIFICATION | 5825-01-166-8106 |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 800.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION AND POLARIZED |
CBME | III CUBIC MEASURE | 0.055 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 17.7 MILLIAMPERES DC SINGLE WINDING |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE TIME |
CRXH | TIME DELAY | 0.0075 SECONDS MAXIMUM FIXED RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 600.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CWJB | ENERGIZING ELEMENT POWER RATING | 180.0 MILLIWATTS |
FEAT | SPECIAL FEATURES | SUPPLIED WITH MOUNTING PAD |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD ALL FUNCTIONS |
![]() |