Mfg Part Number: M430055-18 | Alternate P/N: M43005518 |
NSN : 5925-00-174-3354 | NIIN : 001743354 |
CAGE Code : 21921 | Manufacturer: Rca Corp Distributor And Special |
Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
Alongside NSN 5925-00-174-3354 we have countless other items from Rca Corp Distributor And Special and other leading manufacturers that are readily available for purchase. Nascent Aero lists parts alongside applicable CAGE Codes for the benefit of your search process, such as this particular NSN part M430055-18 being produced under the CAGE Code 21921. As our team members are always available for customers at all times, we guarantee responses to completed quote requests within 15 minutes of submission. Additionally, our team members can walk you through the purchasing process with person-to-person communication every step of the way, ensuring that all your needs are thoroughly and efficiently met. If you have any questions or concerns regarding our offerings and wish to speak with a representative, give us a call or email at any time; we are available 24/7x365.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-174-3354 Item Description: CIRCUIT BREAKER | 5925 | 001743354 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
PSM-3 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE" |
ABHP | OVERALL LENGTH | 2.172 INCHES NOMINAL" |
ADAT | BODY WIDTH | 0.750 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.234 INCHES NOMINAL" |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.812 INCHES NOMINAL" |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.344 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 1" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE" |
CMLP | THREAD QUANTITY PER INCH | 32" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.0 AMPERES AC SINGLE LOCATION AND 3.0 AMPERES DC SINGLE LOCATION" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 110.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 575.0 AC SINGLE LOCATION AND 575.0 DC SINGLE LOCATION" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION" |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 SINGLE LOCATION" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON" |
CPRW | ACTUATOR FUNCTION | RESET" |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 150.000 MAXIMUM AT 200 PCT SINGLE LOCATION" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION" |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION" |
THSD | THREAD SERIES DESIGNATOR | UNC" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW" |
AAQL | BODY STYLE | SINGLE POLE TYPE" |
ABHP | OVERALL LENGTH | 2.172 INCHES NOMINAL" |
ADAT | BODY WIDTH | 0.750 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.234 INCHES NOMINAL" |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.812 INCHES NOMINAL" |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.344 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 1" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE" |
CMLP | THREAD QUANTITY PER INCH | 32" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.0 AMPERES AC SINGLE LOCATION AND 3.0 AMPERES DC SINGLE LOCATION" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 110.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 575.0 AC SINGLE LOCATION AND 575.0 DC SINGLE LOCATION" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION" |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 SINGLE LOCATION" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON" |
CPRW | ACTUATOR FUNCTION | RESET" |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 150.000 MAXIMUM AT 200 PCT SINGLE LOCATION" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION" |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION" |
THSD | THREAD SERIES DESIGNATOR | UNC" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW" |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote