AS9120B, ISO 9001:2015, AND FAA AC 0056B ACCREDITED

Quote for 10673-0030CP With NSN 4820-01-523-4090 of Other - 015234090 03950 4820 Valves Nonpowered Valve Regulating Oxygen System P

Mfg Part Number: 10673-0030CP Alternate P/N: 106730030CP
NSN : 4820-01-523-4090 NIIN : 015234090
CAGE Code : 03950 Manufacturer: Other
Item Name : Valve Regulating Oxygen System P FSC : 4820 Valves Nonpowered
Thank you for your interest in 10673-0030CP part of with NSN 4820-01-523-4090 having CAGE Code 03950 under FSC 4820 Valves Nonpowered manufactured by Other. You have reached our RFQ page for 10673-0030CP part, and completing the form below will allow you to request a quote on this Other product for your comparisons. As you complete our offered form, we ask that you provide us with as much information regarding your needs as you can for the NSN part 10673-0030CP, so that we may best personalize a solution that is fit for you. 015234090 03950 4820 Valves Nonpowered Valve Regulating Oxygen System P

PRODUCT DETAILS “*” Required Fields Are Compulsory

CONTACT INFORMATION


  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Note : We Will Not Share Your Information To Any Third Parties.

  • Upload RFQ SHEET
  • If you have more than one item, upload your spreadsheet here

Alongside NSN 4820-01-523-4090 we have countless other items from Other and other leading manufacturers that are readily available for purchase. Nascent Aero lists parts alongside applicable CAGE Codes for the benefit of your search process, such as this particular NSN part 10673-0030CP being produced under the CAGE Code 03950. As our team members are always available for customers at all times, we guarantee responses to completed quote requests within 15 minutes of submission. Additionally, our team members can walk you through the purchasing process with person-to-person communication every step of the way, ensuring that all your needs are thoroughly and efficiently met. If you have any questions or concerns regarding our offerings and wish to speak with a representative, give us a call or email at any time; we are available 24/7x365.

NSN Information for Part Number 10673-0030CP with NSN 4820-01-523-4090, 4820015234090

NSNFSCNIINCLS HazmatDEMILCancelled NSN
4820-01-523-4090

Item Description:

VALVE,REGULATING,OXYGEN SYSTEM P

4820015234090EANA
CIICHCCESD PMICCriticalityENAC
480.14REGULATINGOXYGEN SYSTEM P
Part NumberISCRNVCRNCCHCCMSDSSADC
FRM-2 1/2IN 0T30PSICP515

Characteristics Data of NSN 4820-01-523-4090, 4820015234090

MRCCriteriaCharacteristic
AAFZBODY MATERIALBRASS
AAQLBODY STYLESTRAIGHT THRU
ACKLMEDIA FOR WHICH DESIGNEDOXYGEN, GASEOUS
ACKMFIRST END CONNECTION TYPETHREADED INTERNAL PIPE
ACKNFIRST END STYLE DESIGNATORGASKET SEAL
ACLJFIRST END THREAD SIZE AND SERIES/TYPE DESIGNATOR0.500 NPT
ACLLFIRST END THREAD DIRECTIONRIGHT-HAND
ACLRSECOND END RELATIONSHIP WITH FIRST ENDIDENTICAL
ADQLFACE TO FACE DISTANCE2.560 INCHES NOMINAL
ADQUFLOW CONTROL DEVICEDIAPHRAGM
ADQZEND CONNECTION QUANTITY2
AEVNREGULATION TYPEAUTOMATIC SINGLE STAGE
AEVRVALVE LOADING METHODSPRING
CRTLCRITICALITY CODE JUSTIFICATIONFEAT
CXCYPART NAME ASSIGNED BY CONTROLLING AGENCYBACK PRESSURE VALVE, SIDE IN, SIDE OUT; CRYOGENIC
FEATSPECIAL FEATURESPRESSURE RANGE IS SET BETWEEN 0 TO 30 PSI; REQUIRES SPECIAL CLEANING AND PACKAGING FOR OXYGEN SERVICE
AAFZBODY MATERIALBRASS
AAQLBODY STYLESTRAIGHT THRU
ACKLMEDIA FOR WHICH DESIGNEDOXYGEN, GASEOUS
ACKMFIRST END CONNECTION TYPETHREADED INTERNAL PIPE
ACKNFIRST END STYLE DESIGNATORGASKET SEAL
ACLJFIRST END THREAD SIZE AND SERIES/TYPE DESIGNATOR0.500 NPT
ACLLFIRST END THREAD DIRECTIONRIGHT-HAND
ACLRSECOND END RELATIONSHIP WITH FIRST ENDIDENTICAL
ADQLFACE TO FACE DISTANCE2.560 INCHES NOMINAL
ADQUFLOW CONTROL DEVICEDIAPHRAGM
ADQZEND CONNECTION QUANTITY2
AEVNREGULATION TYPEAUTOMATIC SINGLE STAGE
AEVRVALVE LOADING METHODSPRING
CRTLCRITICALITY CODE JUSTIFICATIONFEAT
CXCYPART NAME ASSIGNED BY CONTROLLING AGENCYBACK PRESSURE VALVE, SIDE IN, SIDE OUT; CRYOGENIC
FEATSPECIAL FEATURESPRESSURE RANGE IS SET BETWEEN 0 TO 30 PSI; REQUIRES SPECIAL CLEANING AND PACKAGING FOR OXYGEN SERVICE

USA Flag

We are proud to supply every branch of the United States military

Why Choose Us?

Cost Effective COST EFFECTIVE Warrantied inventory at competitive prices
Qucik Search QUICK SEARCH Search the world's largest inventory of electronic components by manufacturer, category or part number
Fastest Delivery FASTEST DELIVERY All inventory ready to ship from our sellers
Quality Assured QUALITY ASSURED We sell only warrantied and traceable parts
Semiconductor's Certifications and Memberships
The only independent
distributor with a
NO CHINA SOURCING Pledge
  • All Orders are fulfilled in the U.S.A.
  • All shipments must comply with U.S.A export laws.
  • No exceptions.
Fallen Heroes Fund

“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.

Thank You for Visiting.

We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.