AS9120B, ISO 9001:2015, AND FAA AC 0056B ACCREDITED

Quote for 2688118-1 With NSN 5945-01-150-3518 of Nipak Inc - 011503518 57311 5945 Relays and Solenoids Relay Electromagnetic

Mfg Part Number: 2688118-1 Alternate P/N: 26881181
NSN : 5945-01-150-3518 NIIN : 011503518
CAGE Code : 57311 Manufacturer: Nipak Inc
Item Name : Relay Electromagnetic FSC : 5945 Relays and Solenoids
Thank you for your interest in 2688118-1 part of with NSN 5945-01-150-3518 having CAGE Code 57311 under FSC 5945 Relays and Solenoids manufactured by Nipak Inc. You have reached our RFQ page for 2688118-1 part, and completing the form below will allow you to request a quote on this Nipak Inc product for your comparisons. As you complete our offered form, we ask that you provide us with as much information regarding your needs as you can for the NSN part 2688118-1, so that we may best personalize a solution that is fit for you. 011503518 57311 5945 Relays and Solenoids Relay Electromagnetic

PRODUCT DETAILS “*” Required Fields Are Compulsory

CONTACT INFORMATION


  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Note : We Will Not Share Your Information To Any Third Parties.

  • Upload RFQ SHEET
  • If you have more than one item, upload your spreadsheet here

Alongside NSN 5945-01-150-3518 we have countless other items from Nipak Inc and other leading manufacturers that are readily available for purchase. Nascent Aero lists parts alongside applicable CAGE Codes for the benefit of your search process, such as this particular NSN part 2688118-1 being produced under the CAGE Code 57311. As our team members are always available for customers at all times, we guarantee responses to completed quote requests within 15 minutes of submission. Additionally, our team members can walk you through the purchasing process with person-to-person communication every step of the way, ensuring that all your needs are thoroughly and efficiently met. If you have any questions or concerns regarding our offerings and wish to speak with a representative, give us a call or email at any time; we are available 24/7x365.

NSN Information for Part Number 2688118-1 with NSN 5945-01-150-3518, 5945011503518

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5945-01-150-3518

Item Description:

RELAY,ELECTROMAGNETIC

59450115035180N
CIICHCCESDPMICCriticalityENAC
U A0
Part NumberISCRNVCRNCCHCCMSDSSADC
BR10T1-5KH4-26VB1CA

Characteristics Data of NSN 5945-01-150-3518, 5945011503518

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH0.880 INCHES MINIMUM AND 0.900 INCHES MAXIMUM"
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH0.680 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.700 INCHES MAXIMUM SINGLE MOUNTING FACILITY"
ABKWOVERALL HEIGHT0.215 INCHES MINIMUM AND 0.235 INCHES MAXIMUM"
ABMKOVERALL WIDTH0.410 INCHES MINIMUM AND 0.430 INCHES MAXIMUM"
ADTVCASE MATERIALMETAL"
ADZCENVIRONMENTAL PROTECTIONHERMETIC"
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.091 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.101 INCHES MAXIMUM SINGLE MOUNTING FACILITY"
AFJNFRAGILITY FACTORMODERATELY RUGGED"
AKDXWINDING QUANTITY1"
AKSLPURPOSE FOR WHICH DESIGNEDGENERAL"
APCNCOIL QUANTITY1"
APNAWINDING DC RESISTANCE RATING1.5 KILOHMS NOMINAL SINGLE WINDING"
APNPDUTY TYPECONTINUOUS"
APNQARC QUENCHING METHODAIR"
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE SINGLE MOUNTING FACILITY"
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE"
CBMEIII CUBIC MEASURE0.091 CUBIC INCHES"
CQYJMOUNTING FACILITY PATTERNIN-LINE SINGLE MOUNTING FACILITY"
CRNGNONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY"
CRTLCRITICALITY CODE JUSTIFICATIONFEAT"
CRXHTIME DELAY0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME"
CSXFOPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING"
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE1.0 AMPERES DC RESISTIVE LOAD"
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE100.0 MILLIAMPERES DC LAMP LOAD"
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE200.0 MILLIAMPERES DC INDUCTIVE LOAD"
CWABMAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS28.0 DC"
FEATSPECIAL FEATURESFAILURE RATE LEVEL 1.0 PERCENT"
TESTTEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI"
TTQYTERMINAL TYPE AND QUANTITY8 WIRE LEAD ALL FUNCTIONS"
ZZZKSPECIFICATION/STANDARD DATA81349-MIL-R-39016/34 GOVERNMENT SPECIFICATION"
ABHPOVERALL LENGTH0.880 INCHES MINIMUM AND 0.900 INCHES MAXIMUM"
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH0.680 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.700 INCHES MAXIMUM SINGLE MOUNTING FACILITY"
ABKWOVERALL HEIGHT0.215 INCHES MINIMUM AND 0.235 INCHES MAXIMUM"
ABMKOVERALL WIDTH0.410 INCHES MINIMUM AND 0.430 INCHES MAXIMUM"
ADTVCASE MATERIALMETAL"
ADZCENVIRONMENTAL PROTECTIONHERMETIC"
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.091 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.101 INCHES MAXIMUM SINGLE MOUNTING FACILITY"
AFJNFRAGILITY FACTORMODERATELY RUGGED"
AKDXWINDING QUANTITY1"
AKSLPURPOSE FOR WHICH DESIGNEDGENERAL"
APCNCOIL QUANTITY1"
APNAWINDING DC RESISTANCE RATING1.5 KILOHMS NOMINAL SINGLE WINDING"
APNPDUTY TYPECONTINUOUS"
APNQARC QUENCHING METHODAIR"
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE SINGLE MOUNTING FACILITY"
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE"
CBMEIII CUBIC MEASURE0.091 CUBIC INCHES"
CQYJMOUNTING FACILITY PATTERNIN-LINE SINGLE MOUNTING FACILITY"
CRNGNONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY"
CRTLCRITICALITY CODE JUSTIFICATIONFEAT"
CRXHTIME DELAY0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME"
CSXFOPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING"
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE1.0 AMPERES DC RESISTIVE LOAD"
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE100.0 MILLIAMPERES DC LAMP LOAD"
CTDLMAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE200.0 MILLIAMPERES DC INDUCTIVE LOAD"
CWABMAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS28.0 DC"
FEATSPECIAL FEATURESFAILURE RATE LEVEL 1.0 PERCENT"
TESTTEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI"
TTQYTERMINAL TYPE AND QUANTITY8 WIRE LEAD ALL FUNCTIONS"
ZZZKSPECIFICATION/STANDARD DATA81349-MIL-R-39016/34 GOVERNMENT SPECIFICATION"

USA Flag

We are proud to supply every branch of the United States military

Why Choose Us?

Cost Effective COST EFFECTIVE Warrantied inventory at competitive prices
Qucik Search QUICK SEARCH Search the world's largest inventory of electronic components by manufacturer, category or part number
Fastest Delivery FASTEST DELIVERY All inventory ready to ship from our sellers
Quality Assured QUALITY ASSURED We sell only warrantied and traceable parts
Semiconductor's Certifications and Memberships
The only independent
distributor with a
NO CHINA SOURCING Pledge
  • All Orders are fulfilled in the U.S.A.
  • All shipments must comply with U.S.A export laws.
  • No exceptions.
Fallen Heroes Fund

“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.

Thank You for Visiting.

We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.