Mfg Part Number: HGE0008 | NSN : 5930-00-364-7569 |
NIIN : 003647569 | CAGE Code : 93408 |
Manufacturer: John Bean Technologies Corporation | Item Name : Switch Thermostatic |
FSC : 5930 Switches |
Alongside NSN 5930-00-364-7569 we have countless other items from John Bean Technologies Corporation and other leading manufacturers that are readily available for purchase. Nascent Aero lists parts alongside applicable CAGE Codes for the benefit of your search process, such as this particular NSN part HGE0008 being produced under the CAGE Code 93408. As our team members are always available for customers at all times, we guarantee responses to completed quote requests within 15 minutes of submission. Additionally, our team members can walk you through the purchasing process with person-to-person communication every step of the way, ensuring that all your needs are thoroughly and efficiently met. If you have any questions or concerns regarding our offerings and wish to speak with a representative, give us a call or email at any time; we are available 24/7x365.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-364-7569 Item Description: SWITCH,THERMOSTATIC | 5930 | 003647569 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
I0ESR | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 2.281 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 2.000 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.312 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 96.0 INCHES NOMINAL" |
AEVU | BULB LENGTH | 1.750 INCHES NOMINAL" |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB" |
AWTN | OPERATING TEMP RATING | -540.0 DEG FAHRENHEIT MINIMUM AND 260.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | BRACKET AND THREADED STUD" |
CMLP | THREAD QUANTITY PER INCH | 24 SINGLE THREADED HOLE" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJX | NOMINAL THREAD SIZE | 0.531 INCHES SINGLE THREADED HOLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSCF | TERMINAL TYPE | WIRE LEAD" |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.3 AMPERES RESISTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 6.5 AMPERES RESISTIVE LOAD FOURTH VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | +180.00/+220.00 ACTUATION POINT DEGREES FAHRENHEIT AND +175.00/+215.00 DEACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 110.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 220.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL THIRD VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS" |
STYL | III STYLE DESIGNATOR | RECTANGULAR" |
THSD | THREAD SERIES DESIGNATOR | UNS SINGLE THREADED HOLE" |
ABHP | III OVERALL LENGTH | 2.281 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 2.000 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.312 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 96.0 INCHES NOMINAL" |
AEVU | BULB LENGTH | 1.750 INCHES NOMINAL" |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB" |
AWTN | OPERATING TEMP RATING | -540.0 DEG FAHRENHEIT MINIMUM AND 260.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | BRACKET AND THREADED STUD" |
CMLP | THREAD QUANTITY PER INCH | 24 SINGLE THREADED HOLE" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJX | NOMINAL THREAD SIZE | 0.531 INCHES SINGLE THREADED HOLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSCF | TERMINAL TYPE | WIRE LEAD" |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.3 AMPERES RESISTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 6.5 AMPERES RESISTIVE LOAD FOURTH VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | +180.00/+220.00 ACTUATION POINT DEGREES FAHRENHEIT AND +175.00/+215.00 DEACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 110.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FOURTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 220.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL THIRD VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS" |
STYL | III STYLE DESIGNATOR | RECTANGULAR" |
THSD | THREAD SERIES DESIGNATOR | UNS SINGLE THREADED HOLE" |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.