Mfg Part Number: 3100U-3-1443 | Alternate P/N: 3100U31443 |
NSN : 5930-01-332-1094 | NIIN : 013321094 |
CAGE Code : 14604 | Manufacturer: Honeywell International Inc Sen |
Item Name : Switch Thermostatic | FSC : 5930 Switches |
Alongside NSN 5930-01-332-1094 we have countless other items from Honeywell International Inc Sen and other leading manufacturers that are readily available for purchase. Nascent Aero lists parts alongside applicable CAGE Codes for the benefit of your search process, such as this particular NSN part 3100U-3-1443 being produced under the CAGE Code 14604. As our team members are always available for customers at all times, we guarantee responses to completed quote requests within 15 minutes of submission. Additionally, our team members can walk you through the purchasing process with person-to-person communication every step of the way, ensuring that all your needs are thoroughly and efficiently met. If you have any questions or concerns regarding our offerings and wish to speak with a representative, give us a call or email at any time; we are available 24/7x365.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-332-1094 Item Description: SWITCH,THERMOSTATIC | 5930 | 013321094 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3100U-3-1443 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 1.180 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 0.380 INCHES MAXIMUM" |
ABPM | BODY DIAMETER | 0.605 INCHES MAXIMUM" |
ABTD | MOUNTING SLOT WIDTH | 0.140 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 0.290 INCHES MAXIMUM" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL" |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.937 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | DISC" |
AWTN | OPERATING TEMP RATING | -80.0 DEG FAHRENHEIT MINIMUM AND 550.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE AND SLOT" |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION" |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG" |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 6.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 7.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT NOT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | -20.00/+500.00 ACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW" |
CTYX | CONTACT STIMULUS RATING | 155.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 165.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 135.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 145.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL THIRD VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
STYL | III STYLE DESIGNATOR | DISC W/FLANGE" |
ABHP | III OVERALL LENGTH | 1.180 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 0.380 INCHES MAXIMUM" |
ABPM | BODY DIAMETER | 0.605 INCHES MAXIMUM" |
ABTD | MOUNTING SLOT WIDTH | 0.140 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 0.290 INCHES MAXIMUM" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL" |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.937 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | DISC" |
AWTN | OPERATING TEMP RATING | -80.0 DEG FAHRENHEIT MINIMUM AND 550.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE AND SLOT" |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION" |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG" |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 6.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 7.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT NOT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | -20.00/+500.00 ACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW" |
CTYX | CONTACT STIMULUS RATING | 155.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 165.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 135.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 145.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL THIRD VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
STYL | III STYLE DESIGNATOR | DISC W/FLANGE" |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.