Mfg Part Number: C16523 | NSN : 5950-00-136-5556 |
NIIN : 001365556 | CAGE Code : 72149 |
Manufacturer: Electronic Transformer Corp | Item Name : Transformer Power |
FSC : 5950 Coils and Transformers |
Alongside NSN 5950-00-136-5556 we have countless other items from Electronic Transformer Corp and other leading manufacturers that are readily available for purchase. Nascent Aero lists parts alongside applicable CAGE Codes for the benefit of your search process, such as this particular NSN part C16523 being produced under the CAGE Code 72149. As our team members are always available for customers at all times, we guarantee responses to completed quote requests within 15 minutes of submission. Additionally, our team members can walk you through the purchasing process with person-to-person communication every step of the way, ensuring that all your needs are thoroughly and efficiently met. If you have any questions or concerns regarding our offerings and wish to speak with a representative, give us a call or email at any time; we are available 24/7x365.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-136-5556 Item Description: TRANSFORMER,POWER | 5950 | 001365556 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
PEI 8415 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.625 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.125 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.625 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT" |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP" |
CRBZ | WINDING OPERATING CURRENT | 3.5 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 3.5 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 4.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 6.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 107.50 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 119.50 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY" |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 5 SECONDARY WINDINGS" |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 14 STANDOFF, SOLDER LUG" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.625 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.125 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.625 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT" |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP" |
CRBZ | WINDING OPERATING CURRENT | 3.5 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 3.5 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 4.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 6.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 107.50 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 119.50 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY" |
FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING; 5 SECONDARY WINDINGS" |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 14 STANDOFF, SOLDER LUG" |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote