Mfg Part Number: NH2-22-3104 | Alternate P/N: NH2223104 |
NSN : 5930-01-170-0251 | NIIN : 011700251 |
CAGE Code : 51171 | Manufacturer: Detroit Switch Inc |
Item Name : Switch Thermostatic | FSC : 5930 Switches |
Alongside NSN 5930-01-170-0251 we have countless other items from Detroit Switch Inc and other leading manufacturers that are readily available for purchase. Nascent Aero lists parts alongside applicable CAGE Codes for the benefit of your search process, such as this particular NSN part NH2-22-3104 being produced under the CAGE Code 51171. As our team members are always available for customers at all times, we guarantee responses to completed quote requests within 15 minutes of submission. Additionally, our team members can walk you through the purchasing process with person-to-person communication every step of the way, ensuring that all your needs are thoroughly and efficiently met. If you have any questions or concerns regarding our offerings and wish to speak with a representative, give us a call or email at any time; we are available 24/7x365.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-170-0251 Item Description: SWITCH,THERMOSTATIC | 5930 | 011700251 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
NH2-222-3264 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT" |
ABKW | OVERALL HEIGHT | 2.812 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 5.188 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.688 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 3.000 INCHES NOMINAL" |
AEVU | BULB LENGTH | 3.000 INCHES NOMINAL" |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL" |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL" |
AFDU | INTERMEDIATE HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL" |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL" |
AGAV | END ITEM IDENTIFICATION | ARLEIGH BURKE CLASS DDG, TICONDEROGA CLASS CG (47), KIDD CLASS DDG, SPRUANCE CLASS DD (963), OHIO CLASS SSN (TRIDENT) SHIP." |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB" |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE" |
CMLP | THREAD QUANTITY PER INCH | 14 SINGLE THREADED HOLE" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJX | NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED HOLE" |
CQYJ | MOUNTING FACILITY PATTERN | OBTUSE TRIANGLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
CSCF | TERMINAL TYPE | SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET" |
CTYM | CONTACT ADJUSTMENT RANGE | +90.00/+180.00 ACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE" |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL" |
STYL | III STYLE DESIGNATOR | RECTANGULAR" |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE THREADED HOLE" |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT" |
ABKW | OVERALL HEIGHT | 2.812 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 5.188 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.688 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 3.000 INCHES NOMINAL" |
AEVU | BULB LENGTH | 3.000 INCHES NOMINAL" |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL" |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL" |
AFDU | INTERMEDIATE HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL" |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL" |
AGAV | END ITEM IDENTIFICATION | ARLEIGH BURKE CLASS DDG, TICONDEROGA CLASS CG (47), KIDD CLASS DDG, SPRUANCE CLASS DD (963), OHIO CLASS SSN (TRIDENT) SHIP." |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB" |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE" |
CMLP | THREAD QUANTITY PER INCH | 14 SINGLE THREADED HOLE" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJX | NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED HOLE" |
CQYJ | MOUNTING FACILITY PATTERN | OBTUSE TRIANGLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
CSCF | TERMINAL TYPE | SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET" |
CTYM | CONTACT ADJUSTMENT RANGE | +90.00/+180.00 ACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE" |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL" |
STYL | III STYLE DESIGNATOR | RECTANGULAR" |
THSD | THREAD SERIES DESIGNATOR | NPT SINGLE THREADED HOLE" |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote